Second Sight TC – Gas leak detector - Bertin Instruments

    Second Sight TC - Optical gas imaging for oil and gas site surveillance

    Second Sight TC – Gas leak detector

    This gas cloud tracking system, based on infrared technology, provides an innovative solution for industrial safety.

    Second Sight TC is an infrared gas imaging camera that detects the presence of gas clouds at a distance of up to several hundred meters.

    This instrument makes visible emissions that may otherwise be invisible to the naked eye. In the event of a toxic or explosive gas leak, the gas cloud is automatically detected, depicted as an overlay on the infrared image and monitored in real time.

    This innovative solution for industrial safety provides key information directly to the central control room with a real-time visual representation of the gas cloud and its motion.

    The network of multiple cameras enables the tracking of the gas cloud in the industrial area. It can also be deployed temporarily to enhance the efficiency of leak detection, as well as protecting critical infrastructure or workers. Bertin shares its expertise at each stage of the design process.

    Get a quote for
    Second Sight TC – Gas leak detector

    GO

    Reasons to choose Second Sight TC – Gas leak detector

    Optical gas imaging with automatic detection

    Multiple gas detection capability

    Suitable for network and remote operation

    24/7 surveillance

    Technology:

    • Infrared spectral imaging

    Catalogue number:

    • 003075-003

    Detection range and Field of View

    • Detection up to 500m with 60×48° FOV
    • Detection up to 1000m with 30×24° FOV

    Detected gas:

    • Gas X: Detect all gas clouds that absorb in band III infrared Ex°: Hydrocarbons, LPG, NH3, S02, CH2CL2

    Time to alarm:

    • in approx. 10 seconds

    Dimensions & Weight:

    • Head camera: 35 x 19 x 24 cm 5.2 kg
    • Processing unit: 26 x 19 x 15 cm 5 kg
    • IECEx configuration: 60 x 50 x 30 cm 35 kg

    Temperature:

    • -20°C to 45°C (operation
    • -20°C to 70°C (storage)

      With IECEx cabinet

    • Temperature range in operation: 0°C / +55°C
    • Temperature range in storage: -20°C to +70°C

    Ingress protection:

    • IP65 / IP66 with IECEx cabinet

    Hazardous classification with IECEx cabinet:

    • Ex Pz IIC T3 Gc tamb -20°C/ +55°C

    The Second Sight TC infrared gas imaging camera is suitable for both one-off short-term monitoring and long-term monitoring, depending on the task and purpose:

    • Automatic detection
    • Real time gas cloud visualization
    • Source point of the leak
    • Movement of the cloud in the plant
    • Network and 24/7 surveillance

    Each gas has its own absorption spectrum and presents typical absorption peaks in infra-red bands II (3 to 5 µm MWIR) and bands III (8 to 14 µm LWIR). Second Sight operates in band III, in order to use the particular peaks to enable the identification of the vast majority of gases. The Second Sight measurement principle uses the scene background as an infra-red source, and image processing algorithms to highlight the presence of a gas cloud in line of sight.

    In the event of an alarm, the presence of a gas cloud is displayed as an overlay on the infrared image. The identification and estimated path length concentration are given in the top left corner and the gas is underlined in red in the gas list.

    The latest version of Second Sight is becoming a universal gas detector with its new detection algorithm Gas X, an unknown gas detection capability that enables the detection of any gas cloud modifying the infrared signature in band III of the observed scene, even if the gas is not listed in the system’s database.

    Battery

    Lightweight and compact battery designed with Lithium-ion technology to offer 5.5 hours of autonomy.

    GPS option

    The GPS coordinates of the Second Sight is given in the Graphic User Interface. It highlights the area of surveillance on a map. Integrated with a compass, it also gives the direction of the Second Sight when used with Pan&Tilt.

    IECEx Cabinet

    Second Sight is integrated into a pressurized stainless steel enclosure for installation in an area where an explosive mixture is not likely to occur under normal operating conditions (zone 2). While a shelter protects the system from direct sunlight, its temperature is regulated by Vortex.

    Supervision software

    This software manages every aspect of Second Sight in a chemical plant (multiple sites are possible). This software checks the various states of Second Sight (alarm, default and power cut off), presents the state of the system on the screen and displays the alarm video if a gas is detected.

    Video

    The only standoff gas detector for real time surveillance and with source localization.

    It’s the perfect solution for critical area surveillance and protection against chemical threats.
    Watch the other Second Sight TC videos

    ANY QUESTIONS? CONTACT AN EXPERT

    Please fill in this form if you wish to contact our sales team or receive further information.

    My Account
    Forgot password ?

    Add a question !